Science – Future of Lithuania / Mokslas – Lietuvos Ateitis, Vol 2, No 5 (2010)

Acoustic Properties of a Renovated Building

Tomas Januševičius
Donatas Butkus

Abstract


The article explores the effects of partitions, ceilings and facades on noise insulation in the renovated different buildings. The conducted experiments were aimed at analyzing partitions of 120 mm brick mounted gypsum panels while other walls were 520 mm thick and plastered on both sides. Under natural conditions, sound insulation factors of facades were measured and compared according to comfort classes. The obtained results revealed that thick brick walls of 520 mm insulated the sound of 58 decibels (dB) (class B). In contrast, 120 mm brick masonry partition reduced sound only to 48 dB which is class E and agrees with the lowest class of sound insulation. We also calculated the sound insulation factor applying three formulas considering the mass law of sound insulation and comparing it with other previous studies. The paper examines and discusses the findings of the performed calculations and measurements.

Article in Lithuanian


Article in: Lithuanian

Article published:

Keyword(s): law of mass; building acoustics; noise; sound insulation factor

DOI: 10.3846/mla.2010.086

Full Text: PDF pdf

Science – Future of Lithuania / Mokslas – Lietuvos Ateitis ISSN 2029-2341, eISSN 2029-2252
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 License.