Admixtures in Spent Plutonium Sources and Gamma-Radiation
Inga Pelanytė
Stasys Motiejūnas
Arūnas Gudelis
Stasys Motiejūnas
Arūnas Gudelis
Abstract
The isotopic composition of several spent smoke detectors containing plutonium has been investigated. The article also presents the calculated results of 241Am and 241Pu activities in smoke detectors. The received values vary from (0.934±0.028) MBq to (91.2±4.6) MBq. The eguivalent dose rate of the established gamma radiation vary from 220 nSv/h to 500 nSv/h. A dose caused by artificial radionuclides in spent smoke detectors was evaluated and compared in the article. It has been found out that due to smoke detectors, an annual dose varies from 0.06 mSv to 0.31 mSv.
Article in Lithuanian
Article in:
English
Article published:
2011-04-12
Keyword(s): smoke detectors; gama spectrometric research; activity; external gama irradiance
DOI: 10.3846/mla.2009.4.08
Science – Future of Lithuania / Mokslas – Lietuvos Ateitis ISSN 2029-2341, eISSN 2029-2252
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 License.