Science – Future of Lithuania / Mokslas – Lietuvos Ateitis, Vol 3, No 5 (2011)

Research on the Aerodynamic Resistance of Trickle Biofilter

Alvydas Zagorskis
Renata Spiečiūtė

Abstract


A four – section trickle biofilter was constructed for experimental research. The filter was filled with the packing material of artificial origin. The material consists of plastic balls having a large surface area. The dependence of biofilter aerodynamic resistance on supply air flow rate and the number of filter sections was determined. The aerodynamic resistance of the biofilter was measured in two cases. In the first case, the packing material of the filter was dry, whereas in the second case it was wet. The experimental research determined that an increase in the air flow rate from 0.043 m/s to 0.076 m/s causes an increase in biofilter aerodynamic resistance from 30.5 to 62.5 Pa after measuring four layers of dry packing material. In case of wet packing material, biofilter aerodynamic resistance after measuring four layers of plastic balls increases from 42.1 to 90.4 Pa.

Article in Lithuanian


Article in: Lithuanian

Article published: 2011-12-19

Keyword(s): trickle biofilter; aerodynamic resistance; microorganisms; packing material

DOI: 10.3846/mla.2011.088