Efficiency Research on Meat Industry Waste Water Treatment Applying the Method of Dissolved Air Flotation
Valentinas Gerasimovas
Robertas Urbanavičius
Robertas Urbanavičius
Abstract
To protect environment from industrial pollution, strict requirements for waste water treatment are imposed. The purpose of research is to establish an optimal ratio of saturated liquid and meat industry waste water. Research included JCC “Traidenis” waste water treatment system installed in JSC “BHJ Baltic”. Investigations into treated waste water indicated that an optimal ratio of waste water and saturated liquid was 2/1 under duration time of 8 minutes. Efficient waste water treatment made 86% and the ratio of waste water and saturated liquid was 2/1.
Article in Lithuanian
Article in:
Lithuanian
Article published:
2012-01-03
Keyword(s): flotation system; meat industry waste water; waste water treatment
DOI: 10.3846/mla.2011.100
Science – Future of Lithuania / Mokslas – Lietuvos Ateitis ISSN 2029-2341, eISSN 2029-2252